Linear Heat Conduction .
Specification of Linear Heat Conduction
A
small-scale accessory designed to introduce students to the principles
of linear heat conduction, and to enable the thermal conductivity of
various solid conductors and insulators to be measured.
- Comprises a heating section, cooling section plus four intermediate section conductor samples and two insulator samples.
- The
heating section, cooling section and one of the intermediate sections
are fitted with thermocouples (eight in total) evenly spread along the
length of the assembled conduction path.
- All sections are insulated to minimize errors due to heat loss.
- Includes a water pressure regulator and a manual flow control valve.
- Includes
a water pressure regulator, an electronic proportioning solenoid valve
to control the cooling water flow rate and a water flow meter.
- Heater power variable up to 60 Watts.
- Water flow rate variable up to 1.5l/min.
- Heating and cooling sections, 25mm diameter.
- The
accessory is mounted on a PVC baseplate, which is designed to stand on
the bench top and connect to the Heat Transfer Service Unit without the
need for tools.
- A comprehensive instruction manual is supplied.
Technical Details:
- The
accessory comprises a heating section and cooling section, which can be
simply clamped together or clamped with interchangeable intermediate
sections between them, as required. The temperature difference created
by the application of heat to one end of the resulting wall and cooling
at the other end results in the flow of heat linearly through the wall
by conduction.
- Thermocouples are positioned along both the
heated sections at uniform intervals of 15mm to measure the temperature
gradient along the sections.
- A pressure regulator is incorporated to minimize the effect of fluctuations in the supply pressure.
- A
control valve enables the flow of cooling water to be varied, if
required, over the operating range of 0-1.5l/min. The cooling water flow
rate is measured by a turbine type flow sensor