Emissions Treatment Pilot Unit .
Emissions Treatment Pilot Unit
Teaching objectives
Study of pressure drop in the waste gas circuit components.
Measuring filter efficiency and clogging as a function of dust particle size.
Measuring cyclone performance as a function of dust particle size, air flow and pressure drop.
Packed Tower scrubber analysis (NTU, HTU, K).
Column hydrodynamics.
Study of liquid waste neutralisation.
Measuring efficiency as a function of dust and acid gas concentration and smoke velocity
Technical specifications
Unit for study of filtration and cyclone separation.
Centrifugal blower
Air flowmeter
Pitot type with manometer
Dust injection system with flow control.
Cyclone in borosilicate glass, diameter 100 mm.
Filter box, with two drawers and a range of filters.
Two U-tube manometers for pressure loss measurements.
Sample of dust of mixed diameters
Dimensions and weight
2 400 x 600 x 2 200 mm – 110 Kg