Domestic Water Heating with Flat Collector .
Water Heating With Flat Collector
Specification Of Water Heating With Flat Collector
- Trainer for investigating the function and operating be haviour of a flat collector
- Solar thermal flat collector with selectively absorbing coating
- Adjustable collector tilt angle
- Solar circulation station with pump, expansion vessel and safety valve
- Hot water circuit with buffer tank, pump and plate heat exchanger
- Four bimetallic thermometers
- Solar controller with temperature, flow and illuminance sensors
- Data logger with use interface
- Operation with solar radiation .
Technical DataOf Water Heating With Flat Collector
Solar Circuit
- Collector
- Absorbing surface: 2,3m²
- Rated throughput: 20...70l/h
- Operating pressure: 1...3bar
- Safety valve 4bar
Hot Water Circuit
- Plate heat exchanger: 3kw, 10 plates
- Buffer tank 70L
Measuring Ranges
- Flow rate: 20...150l/h
- Temperature: 4x 0...120°C