DIGITAL INPUT SIMULATOR .
The simulator must allow studying and analyzing the programming techniques through automatisms freely and imaginatively implemented. Moreover, it must allow the PLC potentialities to be pointed out.
The board must include 32 switches on 4 columns for PLC input enabling, with a LED signalling the on/off state of the individual switch and the possibility of marking the references on special tags that can be cancelled; moreover, 4 outputs at 24 Vdc/1 A must be available, internally powered. The connection to the PLC can be carried out through 2mm terminals.
Power supply: single-phase from mains.
The simulator must be connectable to PLC through two connectors (37-pin type) placed on the backside of the panel.
It must be supplied with connecting cables, educational manual and PLC control software.