Pipe Fitting Loss Demo Panel .
Pipe Fitting Loss Demo Panel
Technical Description of Pipe Fitting Loss Demo Panel
The
experimental arrangement is clearly laid out on a demo panel. The panel
is fitted to a laboratory trolley and is thus flexible in use. Only a
supply of cold water and a drain are required for operation. For the
investigations on the pipes, 10 different pipe sections are provided in
which measuring connections with annular chambers are incorporated. The
measuring connections are connected to the corresponding measuring
equipment using hoses. The pipes can be individually selected for the
experiments using connecting hoses. For pressure measurements, a double
manometer, manometer panel and a battery operated electronic
differential pressure measuring unit are provided. The flow rate is
indicated on a variable-area flow meter. An instruction manual with
detailed description of the theoretical background is supplied.
Specification of Pipe Fitting Loss Demo Panel
- Demo panel for investigating the pressure losses in pipes
- Demo panel on laboratory trolley
- 10 different pipe sections for experiments
- Pipe section selection using hose connections with rapid action hose couplings
- Standard measuring length of 1000mm for pipe friction measurements
- Manometer panel 300mmWG
- Double manometer 850mmWG
- Differential pressure measuring unit 0..2000mbar, battery operated
- Flow rate measurement with variable-area flow meter 1600ltr/h
Technical Data of Pipe Fitting Loss Demo Panel
- Pipe sections
- Section with pipe elbow and bends
- Straight, 18x1mm, L=1000mm, Cu
- Straight, 1/2", L=1000mm, galvanised steel
- Straight, 20x1.5mm, L=1000mm, PVC
- With ball-cock and slanted seat valve NW20
- With gate valve NW 20
- Double line 20x1.5mm, PVC
- Variable-area flowmeter 1600ltr/h
Dimensions and Weight of Pipe Fitting Loss Demo Panel
- l x w x h: 2250 x 700 x 1800 mm
- Weight : approx. 100 kg