Manual Absorption And Stripping Pilot Plant .
Manual Absorption and Stripping Pilot Plant
- Column with a height of 1000 mm packed with Raschig rings
- Heat exchanger with an exchange surface of 0.5 m2 installed at the bottom of the column
- Feed tank with a capacity of 30 litres
- Metering
pump with a flow rate of 270 litres per hour including a pneumatic
actuator that can be controlled by a signal of 0.2 to 1 bar
- 2x pneumatic control valves Cv = 0.2 and 0.08
- Electronic
thermal mass flowmeter with a range of 0 to 600 litres per hour and
electronic display for measuring the flow rate of the gas to be absorbed
- Electronic thermal mass flowmeter with a range of 0 to 6000 litres per hour and electronic display for measuring the flow rate of the carrier gas .
- Electronic differential pressure transmitter with a range of 0 to 200 mm H2O and 4-20 mA output signal
- 3x digital thermocouples with pt100 probes protected by stainless steel shield sleeves
- 3x electronic temperature indicators
- 3x pneumatic manual control valves
- Pipework manufactured from stainless steel
- Electrical control panel in main cabinet
- Emergency stop button.
Power Supply
- 400 Vac 50 Hz three-phase 1000 VA (Other voltages and frequencies available on request)