Losses In Pipe Bends .
Installation Technology Losses In Pipe Bends
Specification Of Installation Technology Losses In Pipe Bends
- Investigation of the pressure loss at pipe elements with different changes in pipe direction and materials
- Pipe elements are commercially standard components in heating and sanitary engineering
- Clear panel mounted on a sturdy, movable frame
- Simply selection of the measuring sections via hose connection with quick-release couplings
- Flow can be adjusted via valves
- Flow measurement using rotameter
- Differential pressure measurement via differential pressure meter with display
Technical Data
- Measuring sections: 2300mm
- Pipe section 1: steel, diameter: 1/2", 90° pipe angle
- Pipe section 2: steel, diameter: 1/2", 90° pipe bend
- Pipe section 3: copper, diameter: 18x1mm,
- 90° pipe angle
- Pipe section 4: copper, diameter: 18x1mm,
- 90° pipe bend
- Differential pressure meter
- Measuring ranges
- Flow rate: 150...1600L/h
- Differential pressure: -350mbar...350mbar