Filling tank .
This module must be used for the demonstration of controlled system characteristics. Slide valves must allow changing the various features of the controlled system. This module must be complete with plug-in device for sensors used to detect the liquid level and it must include a set of 10 transparent foils, printed with a vertical and a horizontal scale with graduation marks. It shall be suitable for labeling with water-soluble markers
Technical features:
•Vessel capacity: 1.5 l minimum
•Three guides for the insertion of sliding valves
• Two hose connections: 8/10 mm Ø
• Three meters transparent rubber hose: 8/10 mm Ø
•Six sliding valves with different opening characteristics and with the same orifice for maximum level
•Connection for 8/10 hose for water entry
•Connection for 8/10 hose for water drain
It must be mounted on an insulated didactic module.